Application of Multistage Vertical Pump as Pressure Compensating Pump in Fire Protection System

In any professional fire protection system, maintaining pipeline pressure is always a vital priority. Fire protection pipelines frequently face the risk of pressure drops due to micro leaks at valve and faucet connections or environmental temperature variations. To solve this problem without starting the main high-capacity fire pump assembly,vertical pump Jockey Pump is a device that plays a key pressure compensation role. The following article will analyze in detail the structure, specifications and reasons why vertical pump is the optimal solution for modern fire protection systems, based on advanced technology from the international standard EVMS pump line.

DETAILED TABLE OF CONTENTS

1. Why is a vertical pump the top choice for a fire protection pressure compensation pump?

  • The Jockey Pump is responsible for maintaining the rated pressure of the automatic fire protection pipeline network (Sprinkler, wall hydrant). When a slight leak occurs, the pressure drops to the first setting threshold,vertical pump will automatically activate to refill the pressure and turn off automatically when the pressure reaches balance.
  • Vertical pump Multiplanes possess ideal properties for this task:

Ability to create high pressure with moderate flow

  • Different from conventional horizontal centrifugal pumps,vertical pump Multi-stage impellers operate on the principle of connecting multiple impellers on a vertical axis. Each impeller will increase a certain pressure level, helping the pump reach a very high pressure head (up to 250 – 300 m) while the flow is maintained at a sufficient level to compensate for water leakage, avoiding wasting energy.

Inline design saves installation space

  • Suction port and discharge port of the line vertical pump Designed on the same straight axis (In-line), combined with a motor placed vertically above the pump body. This structure helps optimize the floor area of ​​the fire protection pump room – which already contains many bulky equipment such as Diesel engine pumps, high-capacity electric pumps, pressure tanks and control cabinets.

High reliability and durable operation

  • Made from high-grade anti-corrosion materials (AISI 304, AISI 316L, standard cast iron),vertical pump has a long life, low vibration and is able to withstand continuous on/off cycles in industrial environments.

2. Standard technical data sheet of vertical pump (EVMS Series)

  • Below are the standard technical data sheets of the line vertical pump Japanese multi-wing technology (Ebara EVMS standard), fully meets the strict requirements in fire protection system design.

Table 1: General operating parameters of EVMS vertical pump

Parameters Standard value
Nominal flow range (Q) 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 m³/h
Maximum working pressure range 1.6 MPa (16 bar) / 2.5 MPa (25 bar) / 3.0 MPa (30 bar) / 3.5 MPa (35 bar)
Working fluid temperature -30°C to +140°C
Minimum Performance Index (MEI) MEI > 0.70 (EVMS 1-20, 45); MEI > 0.60 (EVMS 32, 90)
Hydraulic testing standards ISO 9906:2012 – Grade 3B
Rated rotation speed (50 Hz) 2900 rpm (up to 15 kW) / 2950 rpm (18.5 – 30 kW) / 2975 rpm (37 – 45 kW)
Pipe connection type Round flange, Loose flange, Oval flange, Victaulic®, Clamp

Table 2: Detailed structural materials of vertical pump versions

Components department EVMSG version EVMS version EVMSL version
Impeller Stainless steel AISI 304 (EN 1.4301) Stainless steel AISI 304 (EN 1.4301) Stainless steel AISI 316L (EN 1.4404)
Intermediate casing Stainless steel AISI 304 (EN 1.4301) Stainless steel AISI 304 (EN 1.4301) Stainless steel AISI 316L (EN 1.4404)
Pump shaft (Shaft) AISI 304 / AISI 329A AISI 304 / AISI 329A AISI 316L / AISI 329A
Bottom casing Cast iron (EN-GJL-250 / EN-GJS-400) Stainless steel AISI 304 / ASTM CF8 Stainless steel AISI 316L / ASTM CF8M
Shaft bearings (Sleeve bearing) Tungsten carbide Tungsten carbide Tungsten carbide
Engine Coupling (Coupling) Cast aluminum (≤4.0 kW) / Cast iron (>5.5 kW) Cast aluminum (≤4.0 kW) / Cast iron (>5.5 kW) Cast aluminum (≤4.0 kW) / Cast iron (>5.5 kW)
O-ring seal EPDM/FPM EPDM/FPM EPDM/FPM

Table 3: Electric motor parameters of vertical pump

Engine parameters Configuration for small pumps (≤ 4.0 kW) Configuration for large pumps (≥ 5.5 kW)
Energy efficiency standards IE3 (from 0.75 kW or more) / IE2 (0.37 – 0.55 kW) IE3
Rated voltage (3 phase – 50 Hz) 230/400 ± 10% V 400/690 ± 10% V
Protection level against dust and water IP55 IP55 (up to 11 kW) / IP56 (from 15 kW and up)
Insulation level Class F (Class B temperature rise) Class F (Class B temperature rise)
Thermal protection sensor Built-in PTC sensor (from 1.5 kW) Built-in PTC sensor
IEC flange standards IM B14 IM B5

Table 4: Typical operating range lookup table for fire protection pressure compensation pumps

Vertical Pump Model Power (kW) Pressure head H (m) at Q = 0 Pressure head H (m) at standard working point Optimal flow range (m³/h)
EVMS(.)1 16 0.75 95.5 83.0 (at 1.2 m³/h) 0.72 – 2.4
EVMS(.)1 27 1.5 161.0 140.0 (at 1.2 m³/h) 0.72 – 2.4
EVMS(.)3 10 1.1 73.5 64.5 (at 2.4 m³/h) 1.2 – 4.5
EVMS(.)3 19 2.2 140.0 123.0 (at 2.4 m³/h) 1.2 – 4.5
EVMS(.)5 8 2.2 76.0 64.0 (at 4.5 m³/h) 2.4 – 7.8
EVMS(.)5 14 3.0 133.0 112.0 (at 4.5 m³/h) 2.4 – 7.8
EVMS(.)10 6 2.2 65.5 56.0 (at 9.0 m³/h) 4.5 – 12.0
EVMS(.)10 11 4.0 120.0 103.0 (at 9.0 m³/h) 4.5 – 12.0
EVMS(.)15 4 4.0 59.0 52.0 (at 12.0 m³/h) 7.8 – 24.0
EVMS(.)20 5 7.5 84.2 69.3 (at 18.0 m³/h) 10.8 – 28.8

3. Outstanding technological advantages of multi-stage vertical pumps

  • When used as a fire protection pressure compensation pump, line vertical pump Brings absolute peace of mind thanks to outstanding mechanical improvements:

High performance IE3 motor and PTC thermal protection

  • From a power level of 0.75 kW or more,vertical pump Using a motor that meets IE3 high efficiency standards (according to ErP 2009/125/EC standards), helps reduce starting current and save power consumption. For models of 1.5 kW and above, the PTC temperature sensor is built into the motor coil, preventing the risk of overheating when the pump must operate continuously to compensate for large leaks.

Cartridge mechanical seals are easy to replace

  • The shaft sealing system uses Cartridge Seal mechanical seals (EN 12756 standard). This smart design allows technicians to withdraw and replace the seal assembly directly without dismantling the motor mount or interfering with the pump casing structure. With high-capacity pumps from 5.5 kW, Spacer coupling allows changing seals without needing a crane to lift the heavy engine block.

Low Axial Thrust Load

  • Pump impeller of the line vertical pump The innovation has a special hydraulic structure that helps eliminate most of the axial thrust generated during high-pressure water compression. Thanks to that, the force acting on the bearings of commercial electric motors is significantly reduced, increasing the operating life of the motor.

Diverse connection standards and smart sensors

  • The pump body is equipped with smart plug solutions for air ventilation, water priming, sediment discharge and has a built-in port for commercial exhaust/suction pressure sensors. A variety of mechanical connections from DIN EN 1092-2 standard flanges, Victaulic® grooved joints to Clamp joints make integration into existing fire protection piping systems quick.

4. Instructions for calculating and selecting a vertical shaft pump to compensate for fire protection pressure

  • To choose the correct model vertical pump For fire suppression systems, design engineers need to follow the following calculation steps:

1. Determine the pressure compensation flow ($Q_{compensation}$)

  • The flow rate of the pressure compensation pump must not be too large (to avoid overwhelming the main fire pump) and must not be too small (to ensure fast pressure recovery time).
  • Normal standards: Pressure compensation pump flow $Q_{bù}$ is taken as approx 1% to 5% main fire pump rated flow ($Q_{main}$), or normally within the magnetic range 1.0 m³/h to 10 m³/h for high-rise buildings, apartments, small and medium factories.

2. Determine the pressure compensation head ($H_{compensation}$)

  • The maintained pressure of the pressure compensation pump must always be higher than the starting pressure of the main fire pump to avoid mistakenly activating the main pump when there is only a normal leak:
  • Experience formula:$$H_{compensation} = H_{system\system} + (0.5 \div 1.0\ \text{bar})$$(equivalent to a pressure head 5 to 10 meters higher than the main pump’s working point).

3. Check safe working parameters

  • Maximum working pressure (Max working pressure): Must ensure the total static pressure of the water column plus the pressure generated at the Shut-off head of the valve.vertical pump Do not exceed the pressure rating of the pump body (16 bar, 25 bar or 35 bar) and pipes.
  • NPSH safety margin: When calculating water suction from underground tanks, it is necessary to ensure that the available NPSH of the system is greater than the required NPSH of the pump by at least a safety margin of 0.5 m.

5. Important notes when installing a pressure-compensating vertical pump

  • To cluster vertical pump Stable operation in the fire protection diagram, need to comply with technical installation principles:
  • Installing a pressure tank: It is mandatory to install a rubber membrane pressure tank (capacity from 24L to 100L or larger) at the discharge end of the pump.vertical pump to buffer pressure, eliminate the Water Hammer phenomenon and reduce the frequency of continuous switching of the pressure relay.
  • Install one-way valve: Arrange a one-way valve right behind the discharge nozzle of the pressure compensation pump to prevent high-pressure water flow from bouncing back and damaging the pump impeller when the pump stops suddenly.
  • Exhaust air before test run: Use the Air ventilation plug on the top of the pump body to push all air bubbles out of the impeller chamber before operating. Absolutely do not let it vertical pump Run dry, avoid burning the contact surface of the SiC/Carbon mechanical seal.
  • Inverter operation (VFD): Can be combined vertical pump with inverter for flexible speed control, keeping pipeline pressure absolutely stable and starting smoothly.

6. Conclusion

  • Vertical pump Multi-stage is the optimal and irreplaceable technical solution as a pressure compensation pump for fire protection systems. With a wide pressure range of up to 35 bar, outstanding space saving ability, IE3 energy efficiency and mechanical durability according to Japanese technology standards, the vertical pump like Ebara EVMS ensures the fire fighting system is always in the highest state of combat readiness when a fire incident occurs.