The Ebara GS pump series is famous for its high performance and durable design. However, because this is an End Suction Volute Pump, the pump head and motor are connected via coupling on a common base. Work AlignmentAccuracy is the decisive factor for the machine to operate smoothly, without vibration and to achieve maximum longevity.
1. Why do we have to center the axis for the line?Ebara GS?
Although Ebara’s steel base is very sturdy, during transportation or tightening foundation bolts, the base may be slightly deformed. Correct alignment helps:
-
Reduce vibration and noise:Avoid resonance phenomena that are harmful to the piping system.
-
Protecting seals and bearings:Limits unwanted centripetal forces acting on the shaft.
-
Energy saving:Reduces power loss due to friction at joints.
2. Common types of shaft eccentricity
Before starting, technicians need to understand two types of deviations:
-
Parallel Misalignment:The centers of the two axes lie on two parallel lines but do not overlap.
-
Angular Misalignment:The two axes form an angle at the joint point.
3. Standard 5-step alignment process
Step 1: Pre-alignment
-
Make sure the base is clean and there is no rust under the motor base.
-
Check for the “Soft Foot” phenomenon by tightening/releasing each tripod bolt and using a dial gauge to measure play.
Step 2: Roughly align with a straightedge
Use a ruler or straight ruler to place it on the joint in 4 positions (top, bottom, left, right). Adjust the motor so that the gauge lies flat on both halves of the coupling. This step helps bring errors to the allowable clearance before using accurate measuring equipment.
Step 3: Use specialized measuring tools
There are two common methods for streaming Ebara GS:
-
Dial Indicator:Use the Rim and Face measurement methods. This is the traditional, accurate way but requires good calculation skills.
-
Laser centering machine:The most modern method, gives instant results and guides you on how many shims you need to add/remove on which leg.
Step 4: Adjust with Shims
-
Use stainless steel pads placed under the motor foot to adjust height (parallel deviation) and tilt (angular deviation).
-
Note:Do not insert more than 3-4 pieces of shim under one machine leg to avoid spring elasticity.
Step 5: Check again after tightening
Tighten all bolts diagonally. Then, measure again one last time. For line Ebara GS, the allowable deviation is usually in the range 0.05mmcome 0.1mmdepending on rotation speed (1500rpm or 3000rpm).
4. Mistakes to avoid
-
Align when the tube is not installed:Always have to re-center the shaft afterconnected the inlet-outlet pipe, as the weight of the pipe may pull the pump head out of position.
-
Ignore thermal expansion:For hot water pump applications, it is necessary to calculate the thermal expansion of the motor when it reaches operating temperature.
-
Not using the correct type of coupling:Make sure the gap between the two coupling faces (Gap) is correct according to Ebara technical documents.
Conclusion
Shaft alignment is not a “one and done” task, but should be checked periodically during maintenance. One system Ebara GS Correctly aligned will operate durably, helping businesses optimize repair and operating costs.