Standard flange and industrial pipe connections on popular Ebara pump lines

In industrial pump installation, mastering the Flange Standards (Flange Standards)not only helps the system operate tightly but also ensures interchangeability during maintenance and replacement. For the Ebara brand, pump lines are designed according to strict international standards such as ISO, DIN, JIS or ANSI.

This article will review the popular flange connection types on current Ebara pump lines.


1. Common flange standards on Ebara pumps

Ebara is a global brand, so their products comply with different standards depending on the market and model:

European Standard (EN 1092 / DIN)

This is the most common standard on Ebara lines produced in Italy (Ebara Italy).

  • Characteristics:Usually the symbol is PN10, PN16, PN25. The accompanying number represents the maximum working pressure (for example, PN16 is 16 bar).

  • Applicable pump series:Ebara 3M, 3D, MD, Matrix/EVM booster.

Japanese Standards (JIS)

Popular on pumps made in Japan or heavy duty submersible pumps.

  • Characteristics:Usually the symbol is JIS 10K, JIS 16K, JIS 20K.

  • Applicable pump series:Ebara GS, Ebara DL, DF, SZ (mixed shaft pump).

American Standard (ANSI/ASME)

Often appears on pump lines exported to the US market or specific oil, gas and chemical projects.

  • Characteristics:Notation by Class (eg Class 150, Class 300).


2. Connection details on typical Ebara pump lines

2.1. Stainless steel horizontal pump line (Ebara 3M, 3D)

These pump lines often use standard cast flanges EN 1092-2 (PN16).

  • Note when installing:3M Ebara flanges usually have a flat surface (Flat Face – FF). When connecting to pipes, you should choose steel or stainless steel flanges with the same bolt hole standards to avoid eccentricity.

2.2. Ebara GS series of separate shaft pumps

The GS series is a globally standardized pump series, so its flanges are very flexible:

  • Suction/exhaust throat:Usually follows standards EN 1092-2 PN16or JIS 10K/16K.

  • Characteristics:GS pump body is made of thick cast iron, with raised face (RF) to increase sealing ability when using gaskets.

2.3. Submersible wastewater pump series (Ebara DL, DF, DML)

With submersible pumps, flange connections are divided into two types:

  • Free Standing connection:Bent elbow flanges are usually standard JIS 10K.

  • Quick coupler connection (QDC):The flange of the sliding mount must be compatible with the flange of the pump body. Ebara designs universal bolt holes to accommodate both DIN and JIS standards in some models.


3. Common errors when connecting flanges

Confusion between flange standards is the leading cause of problems:

  1. Eccentric bolt hole:PN16 and JIS 10K flanges have almost the same outside diameter but different number of holes or hole center distance. Intentionally crossing the bolts will cause residual stress that will crack the cast iron flange.

  2. Wrong type of gasket:Using gaskets that are too thick or not suitable for temperatures/chemicals will cause leaks immediately upon pressure testing.

  3. Tightening bolts unevenly:Not tightening in a star shape (symmetrical) will lead to warping of the flange, causing water seepage on one side.


4. Quick lookup table for bolt hole numbers according to PN16 standard (Most popular)

Throat size (DN) Hole center diameter (PCD) Number of bolt holes Bolt size
DN50 125 mm 4 M16
DN65 145 mm 4 M16
DN80 160 mm 8 M16
DN100 180 mm 8 M16
DN150 240 mm 8 M20

5. Technical advice from experts

  • Check the molding symbol on the pump body:Ebara often embosses the pressure standard (e.g. “PN16” or “10K”) right on the flange.

  • Material homogeneity:If the pump has a stainless steel body (3M series), priority should be given to stainless steel pipe flanges to avoid electrochemical corrosion at the contact point.

  • Using flexible joints:Always install a Rubber Expansion Joint immediately behind the pump flange to eliminate vibration and protect the pump flange from cracking due to thermal expansion of the pipeline.

    T&C INDUSTRIAL DISTRIBUTION JOINT STOCK COMPANY (TCID)

    • Hotline: 090 307 1804
    • Website:ebaravietnam.vn/
    • Address:384/42 Nam Ky Khoi Nghia, Xuan Hoa Ward, Ho Chi Minh