Ebara DW Single Impeller Submersible Wastewater Pump: High Performance Wastewater Suction Solution

Official authorized distributor T&C Industrial Distribution (T-CID)

1. Overview of Ebara DW Single Impeller Submersible Wastewater Pump

  • Flow Optimization: Helps the pump achieve higher pressure head and larger flow compared to vortex flow at the same power level.
  • Good solids handling: Allows solid impurities up to size 50mm Passes through easily without causing blockage.
  • High durability: The entire pump body, impeller and motor shell are made from high-grade 304 stainless steel, effectively preventing corrosion in complex wastewater environments.

2. Structural Features and High Quality Manufacturing Materials

Main structural materials

  • Pump housing, housing cover & Motor body: AISI 304 stainless steel.
  • Impeller: AISI 304 stainless steel has single channel blade design.
  • Pump shaft (Shaft): Stainless steel AISI 304 (parts in contact with liquid).
  • Handle & Stand: AISI 304 stainless steel is sturdy and convenient for moving and installation.

Optimal Double Mechanical Seal mechanism

  • Pump side seal: Silicon Carbide / Silicon Carbide / NBR (SiC/SiC/NBR) – super hard, resistant to friction and chemical corrosion.
  • Motor side seal: Carbon / Ceramic / NBR – ensures absolute tightness.

3. Detailed Technical Specifications Table Ebara DW

Technical specifications Detailed value
Type of pumped liquid Dirty water, domestic and industrial wastewater
Maximum liquid temperature 40°C
Maximum solid impurity size 50 mm (spherical shape)
Maximum submersion depth 7 m
Pump impeller type Single channel impeller
Rotation speed 2-pole self-contained, ~2800 rpm (50Hz)
Protection level / Insulation level IP X8/Class F
Voltage used 1 phase (230V ± 10%) or 3 phase (400V ± 10%)
Engine capacity 0.55 kW – 2.2 kW (0.75 HP – 3 HP)
Discharge port Thread G 2 (UNI ISO 228) or Flanged Face DN 50 (DWF series)

4. Performance Lookup Table (Selection Chart)

Pump Model Power (kW) Power (HP) Q = 0 m³/h (0 l/min) Q = 6 m³/h (100 l/min) Q = 12 m³/h (200 l/min) Q = 18 m³/h (300 l/min) Q = 24 m³/h (400 l/min) Q = 30 m³/h (500 l/min) Q = 36 m³/h (600 l/min) Q = 42 m³/h (700 l/min) Q = 48 m³/h (800 l/min)
DW 75 0.55 0.75 8.0m 6.3m 4.8m 3.4m 2.2m – – – –
DW 100 0.75 1.0 10.6m 8.7m 7.1m 5.5m 4.0m 2.6m – – –
DW 150 1.1 1.5 13.1m 11.3m 9.5m 7.7m 5.9m 4.2m 2.4m – –
DW 200 1.5 2.0 16.6m 15.0m 13.3m 11.4m 9.5m 7.5m 5.4m 3.3m –
DW 300 2.2 3.0 20.0m 18.3m 16.6m 15.1m 13.3m 11.3m 9.3m 7.2m 5.0m

5. Motor Data & Voltage Table (Motor Data)

Pump Model Voltage Power (kW) Capacitor (µF) Capacitor voltage (V) Full load current (A) Starting current (A)
DW 75 M 1 phase (230V) 0.55 20 450 3.9 17
DW 75 3 phase (400V) 0.55 – – 1.5 8.5
DW 100M 1 phase (230V) 0.75 25 450 5.9 26
DW 100 3 phase (400V) 0.75 – – 2.1 14.2
DW 150M 1 phase (230V) 1.1 31.5 450 7.3 35
DW 150 3 phase (400V) 1.1 – – 2.8 24.2
DW 200 3 phase (400V) 1.5 – – 3.6 30
DW 300 3 phase (400V) 2.2 – – 5.0 45

6. Outstanding Advantages of Ebara DW Single Impeller Pump

  • Ability to pump wastewater containing large impurities: The single blade allows solids up to a maximum diameter of 50mm to be discharged without being trapped, suitable for untreated raw wastewater.
  • Absolutely anti-corrosion: Thanks to its construction entirely in AISI 304 stainless steel, the pump is capable of operating well in mild chemical environments, mildly salty or weakly acidic wastewater.
  • Safe & Durable: The motor has a built-in thermal relay to protect against overload (for single-phase lines). Dual seals running in the oil chamber help dissipate heat well, improving operating life.
  • Automatic Options (Automatic Version): The single-phase line has a built-in float switch that helps the pump automatically turn on when the water rises (about 460-470mm) and turns off when the water recedes (about 250-260mm).
  • Diverse connection types: Provide internal thread connection (DW standard), sump joint connection (DW F) or size-optimized design (DW FZ).

7. Practical Application of Ebara DW Submersible Pump

  • Drainage of domestic wastewater: Suctioning wastewater from septic tanks and septic tanks of high-rise buildings, apartments, hotels, and shopping centers.
  • Industrial wastewater treatment: Wastewater transfer pump in textile and dyeing factories, food factories, seafood processing factories, and industrial clusters.
  • Anti-flood drainage: Suction water to flood basements, manholes, and underground works when heavy rains or high tides occur.
  • Agriculture & Fisheries: Pumping water supply and drainage for livestock farms and aquaculture lakes.

8. Instructions for Choosing Products to Achieve Optimal Efficiency

  • Determine the power supply voltage: Select version DW M(230V – 1 phase) for civil works or DW(400V – 3 phase) for industrial systems.
  • Calculate pressure head and flow: Based on the performance lookup table to choose the model with the optimal working point (Best Efficiency Point). Note: Do not operate the pump at a flow rate below 10% of the optimal point to avoid overheating the motor.
  • Need for automation: If installing for a small sump without a control cabinet, you should choose a model with an automatic float built in (for example: DW 100 MA).

9. Conclusion

CONTACT YOUR TECHNICAL SUPPORT REPRESENTATIVE AND QUOTE

General Distributor T&C Industrial Distribution (T-CID)
📞
Technical contact hotline: 090 307 1804
📍
Warehouse general agent address:384/42 Nam Ky Khoi Nghia, Xuan Hoa Ward, City. Ho Chi Minh
🌐
Look up online catalogs: ebaravietnam.vn